Release Notes for Win CE AEGIS Client
Version 2.1.7
September 2005
Version 2.1.7 replaces versions 2.1.4 and 2.1.5.
Problems
fixed between 2.1.4 and 2.1.7
Workarounds
for all Tested Platforms
Problems fixed between 2.1.4 and 2.1.7
- Re-authentication without fast resumption and
EAP-PEAP/MSCHAPv2
During a PEAP session resumption, the client now
conditionally attempts a fast reconnect based on whether or not the server
requests a full authentication. (Ref #10471)
- WPA-PSK with only numeric characters
Failures when
using Pre-Shared Keys with numeric characters only has been fixed. (Ref
#10725)
- Providing credentials for tunneled authentication
When setting the "ask" mode for providing the tunneled
(protected) credentials, the following issues have been fixed: (Ref
#10824,10830)
- Setting of the unprotected identity (in the upper pane) continues to be
allowed and is passed in the identity response message.
- Entering tunneled credentials remains disabled even when the
authentication protocol is changed.
- Selective Device Issues:
- Incomplete scan list (Samsung chip set)
An issue
with some devices (that exhibit slow internal refreshing) with maintaining
an updated scan list has been fixed. (Ref #10846)
- Suspend/Resume operation (TI chip set)
An issue with
recovering the client's operation after a suspend/resume operation has been
fixed. (Ref #10583)
- WPA support (TI chip set)
Support for WPA has been
fixed. (Ref #10569)
- Access Point disassociation (Motorola)
An issue with
disassociating from an access point has been fixed. (Ref #11161)
- WPA Setting (Motorola)
Full access to all WPA
Setting modes has been fixed. (Ref #11162)
top
Workarounds for all Tested Platforms
- Network names
Since the BSSID of the network is allowed to
contain unprintable characters, non-text squares may show up in the names in
the available network list. (Ref #1328)
Workaround: Ignore
the characters if you believe the SSID is valid, or ignore the network entry
if it appears that the driver is malfunctioning.
- Certificate installation
If while installing a certificate on
the handheld device you enter a wrong password you will be correctly notified
by a message reading “Incorrect password”. However a follow-up prompt to allow
entering the password again is missing. (Ref #1791)
Workaround: Run the certadd utility again.
top