Release Notes for Win CE AEGIS Client
September 2005
Version 2.1.7 replaces versions 2.1.4 and 2.1.5.
Problems fixed between 2.1.4 and 2.1.7
-
Re-authentication without fast resumption and EAP-PEAP/MSCHAPv2
During a PEAP session resumption, the client now conditionally attempts a fast reconnect based on whether or not the server requests a full authentication.(Ref #10471)
-
WPA-PSK with only numeric characters
Failures when using Pre-Shared Keys with numeric characters only has been fixed. (Ref #10725)
-
Providing credentials for tunneled authentication
When setting the "ask" mode for providing the tunneled (protected) credentials, the following issues have been fixed: (Ref #10824,10830)
-
Setting of the unprotected identity (in the upper pane) continues to be allowed and is passed in the identity response message.
-
Entering tunneled credentials remains disabled even when the authentication protocol is changed.
-
Selective Device Issues:
-
-
Incomplete scan list (Samsung chip set)
An issue with some devices (that exhibit slow internal refreshing) with maintaining an updated scan list has been fixed. (Ref #10846)
-
Suspend/Resume operation (TI chip set)
An issue with recovering the client's operation after a suspend/resume operation has been fixed. (Ref #10583)
-
WPA support (TI chip set)
Support for WPA has been fixed. (Ref #10569)
-
Access Point disassociation (Motorola)
An issue with disassociating from an access point has been fixed. (Ref #11161)
-
WPA Setting (Motorola)
Full access to all WPA Setting modes has been fixed. (Ref #11162)
Workarounds for all Tested Platforms
-
Network names
Since the BSSID of the network is allowed to contain unprintable characters, non-text squares may show up in the names in the available network list. (Ref #1328)
Workaround:
Ignore the characters if you believe the SSID is valid, or ignore the network entry if it appears that the driver is malfunctioning.
-
Certificate installation
If while installing a certificate on the handheld device you enter a wrong password you will be correctly notified by a message reading “Incorrect password”. However a follow-up prompt to allow entering the password again is missing. (Ref #1791)
Workaround: Run the certadd utility again.
|